Elevating dock levellers can be built in virtually any size and capacity required for the application.
They provide the ability to service trucks at any height and can also offer fork trucks access to ground level.


  • Available in 30,000lbs (13.6t) or 50,000lbs (22.0t) capacity ratings as standard
  • Heavy-duty version up to 80,000lbs (36t) capacity available for the most demanding loading conditions
  • Heavy-duty I-beam under-deck support ensures high structural strength against rolling loads
  • Heavy-duty hydraulic system with high-quality power pack and cylinders from reputable manufacturers
  • Maintained tilt design compensates for uneven loading conditions
  • Standard working range +/- 12″ (+/- 300 mm) up/down, customisable if necessary to suit higher trucks or low loading docks
  • Fail-safe safety design
  • Weatherproof IP 55 control box
  • Standard working range toe guards supplied
  • Comes with one set of moulded rubber dock bumpers as standard

Vertical Storing Dock Leveller is the perfect loading dock solution for facilities
and applications that require strict climate control or high cleanliness levels.
皇冠体育网 It improves internal temperature control, reduces the risk of door damage and minimises debris entry.




TR IN

For moderate-to-high traffic indoor or outdoor environments.
• 1,500,000 operating cycles
• 6,000 x 5,800 mm max size
皇冠体育网 • Galvanised steel door structure & drive shaft

TECHNICAL SPECIFICATION TR IN
WIDTH (mm) 2,000–6,000
HEIGHT (mm) 1,800–5,800
OPENING SPEED (m/s) 2.0 - size up to 3,000 x 3,000 mm
1.5 - size up to 5,000 x 5,000 mm
1.0 - size up to 5,800 x 6,000 mm
CLOSING SPEED (m/s) 0.8 or as opening speed
FABRIC TYPE PVC coated polyester
FABRIC WEIGHT (g/m2) 900
PANEL TYPE
(OPTIONAL)
Vision, 1 mm thick transparent PVC
TRACK GUIDES Extruded polyethylene
WIND LOAD EN12424:2000
• Class 3 (3,000 x 3,000 mm)
• Class 2 (5,000 x 5,000 mm)
• Class 1 (5,800 x 6,000 mm)
OPERATING TEMPERATURE RANGE (°C) • -15 to +70, indoor drive
• -5 to +70, outdoor drive
• -35 to +70, drive & side frame heating systems
CONTROL UNIT • Painted steel housing, 470 x 290 x 200 mm
• IP54 ingress protection; frequency converter
OPERATOR Supply 240V/50–60Hz; 400V/50–60Hz; 1.5kW motor power
• IP54 ingress protection
• Limit positions by encoder
SAFETY • Built to EU standards - EN 13241 CN
• Photocells (1 pair), 500 mm from floor level
• Door bottom safety sensor
• Power failure triggers auto-open to 2,000 mm
height for counterweighted doors (optional)
• Transparent window (not available for cold storage)
• Flashing light
• Siren (optional)

Help us to specify the project for you, by submitting the form below

Protection with aesthetic values.
皇冠体育网 Heavy-duty rolling shutter doors for normal temperature warehouses, providing a high level of security and protection.

TECHNICAL SPECIFICATION Roller Shutter Door
WIDTH (mm) 2,000–12,000
HEIGHT (mm) 1,800–12,000
SLAT THICKNESS (mm) 0.6, 0.8, 1.0, 1.2 and 1.5
SLATS Roll-formed first grade high-quality phosphated galvanised steel
COATING Powder coated
OPERATION Push button control

40 mm/80 mm
TP 40/TP 80

For excellent insulation against the elements and temperature loss.
• 25,000 operating cycles
皇冠体育网 • Durable powder-coated springs

TECHNICAL SPECIFICATION TP40 TP80
MODEL TP 40 TP 80
PANEL THICKNESS (mm) 40 80
HEATING ELEMENT N/A N/A Along side tracks
WIDTH (mm) 2,000–8,000 2,000–6,000 2,000–8,000
HEIGHT (mm) 2,000–8,000 2,000–5,000 2,000–5,000
THERMAL INSULATION (R-VALUE) (m2. c/w) 1.13 2.3 3.3
WIND LOAD Class 2 (EN12424:2000)
AIRTIGHTNESS Class 4 (EN12426:2000)
WATERTIGHTNESS Class 3 (EN12425:2000)
ACUSTIC INSULATION <35 dB
DOOR PANEL WEIGHT (kg/m2) 10.9 16.3 16.3
THICKNESS OF STEEL CASING (mm) 0.35

TR EX

For moderate-to-high traffic indoor or outdoor environments.
• 1,500,000 operating cycles
• 6,000 x 5,800 mm max size
皇冠体育网 • Galvanised steel door structure & drive shaft

TECHNICAL SPECIFICATION TR EX
WIDTH (mm) 2,000–6,000
HEIGHT (mm) 1,800–5,800
OPENING SPEED (m/s) 2.0 - size up to 3,000 x 3,000 mm
1.5 - size up to 5,000 x 5,000 mm
1.0 - size up to 5,800 x 6,000 mm
CLOSING SPEED (m/s) 0.8 or as opening speed
FABRIC TYPE PVC coated polyester
FABRIC WEIGHT (g/m2) 900
PANEL TYPE
(OPTIONAL)
Vision, 1 mm thick transparent PVC
TRACK GUIDES Extruded polyethylene
WIND LOAD EN12424:2000
• Class 3 (3,000 x 3,000 mm)
• Class 2 (5,000 x 5,000 mm)
• Class 1 (5,800 x 6,000 mm)
OPERATING TEMPERATURE RANGE (°C) • -15 to +70, indoor drive
• -5 to +70, outdoor drive
• -35 to +70, drive & side frame heating systems
CONTROL UNIT • Painted steel housing, 470 x 290 x 200 mm
• IP54 ingress protection; frequency converter
OPERATOR Supply 240V/50–60Hz; 400V/50–60Hz;
1.5kW motor power
• IP54 ingress protection
• Limit positions by encoder
SAFETY • Built to EU standards - EN 13241 CN
• Photocells (1 pair), 500 mm from floor level
• Door bottom safety sensor
• Power failure triggers auto-open to 2,000 mm
height for counterweighted doors (optional)
• Transparent window (not available for cold storage)
• Flashing light
• Siren (optional)

Food Industry TR FO

For food processing industries.
• 1,500,000 operating cycles
• 4,000 x 4,000 mm max size
• Stainless steel AISI 304 door structure & drive shaft
• Washable door & track

TECHNICAL SPECIFICATION TR FO
WIDTH (mm) 2,000–4,000
HEIGHT (mm) 1,800–4,000
OPENING SPEED (m/s) 1.9
CLOSING SPEED (m/s) 0.8 or as opening speed
FABRIC TYPE PVC coated polyester
FABRIC WEIGHT (g/m2) 900
PANEL TYPE
(OPTIONAL)
Vision, 1 mm thick transparent PVC
TRACK GUIDES Extruded polyethylene
WIND LOAD EN12424:2000
• Class 3 (3,000 x 3,000 mm)
• Class 2 (4,000 x 4,000 mm)
OPERATING TEMPERATURE RANGE (°C) • -15 to +70, indoor drive
• -5 to +70, outdoor drive
• -35 to +70, drive & side frame heating systems
• Below -5, no windows
CONTROL UNIT • Painted steel housing, 470 x 290 x 200 mm
• IP54 ingress protection; frequency converter
OPERATOR Supply 240V/50–60Hz; 400V/50–60Hz; 1.5kW motor power
• IP54 ingress protection
• Limit positions by encoder
SAFETY • Built to EU standards - EN 13241 CN
• Photocells (1 pair), 500 mm from floor level
• Door bottom safety sensor
• Power failure triggers auto-open to 2,000 mm height for counterweighted doors (optional)
• Transparent window (not available for cold storage)
• Flashing light
• Siren (optional)

Cold Storage TR FR

Perfect for freezing conditions.
• 1,500,000 operating cycles
• 3,500 x 4,000 mm max size
• Galvanised steel door & drive shaft

TECHNICAL SPECIFICATION TR FR
WIDTH (mm) 2,000–3,500
HEIGHT (mm) 1,800–4,000
OPENING SPEED (m/s) 1.5
CLOSING SPEED (m/s) 0.8 or as opening speed
FABRIC TYPE PVC coated polyester
FABRIC WEIGHT (g/m2) 900
PANEL TYPE
(OPTIONAL)
Vision, 1 mm thick transparent PVC
WIND LOAD EN12424:2000
• Class 1 (3,500 x 4,000 mm)
OPERATING TEMPERATURE RANGE (°C) • -15 to +70, indoor drive
• -5 to +70, outdoor drive
• -35 to +70, drive & side frame heating systems
• Below -5, no windows
CONTROL UNIT • Painted steel housing, 470 x 290 x 200 mm
• IP54 ingress protection; frequency converter
OPERATOR Supply 240V/50–60Hz; 400V/50–60Hz; 1.5kW motor power
• IP54 ingress protection
• Limit positions by encoder
SAFETY • Built to EU standards - EN 13241 CN
• Photocells (1 pair), 500 mm from floor level
• Door bottom safety sensor
• Flashing light
• Siren (optional)

Large Doors
TR LA

For large openings or high wind loads.
• 1,000,000 operating cycles
• 12,000 x 7,000 mm max size
皇冠体育网 • Galvanised steel tracks, covers & tubes

TECHNICAL SPECIFICATION TR LA
WIDTH (mm) 2,000–12,000
HEIGHT (mm) 2,000–7,000
OPENING SPEED (m/s) 1.0 - size up to 5,000 x 5,000 mm
0.6 - size up to 12,000 x 7,000 mm
CLOSING SPEED (m/s) 0.5
FABRIC TYPE PVC coated polyester
FABRIC WEIGHT (g/m2) 900
PANEL TYPE
(OPTIONAL)
Vision, 1 mm thick transparent PVC
OPEN/CLOSE MECHANISIM Belt system
WIND LOAD EN12424:2000
• Class 4 (up to 3,000 mm width)
• Class 3 (up to 5,000 mm width)
• Class 2 (up to 8,000 mm width)
• Class 1 (up to 12,000 mm width)
OPERATING TEMPERATURE RANGE (°C) • -15 to +70, indoor drive
• -5 to +70, outdoor drive
• -35 to +70, drive & side frame heating systems
• Below -5, no windows
CONTROL UNIT/OPERATOR • Supply 240V/50–60Hz; 400V/50–60Hz; 0.75–2.2kW motor power
• IP54 ingress protection
• Limit positions by encoder
SAFETY • Built to EU standards - EN 13241 CN
• Photocells (1 pair), 500 mm from floor level
• Door bottom safety sensor
• Power failure triggers auto-open to 2,000 mm height for counterweighted doors (optional)
• Transparent window (not available for cold storage)
• Flashing light
• Siren (optional)

TR SP

For better security including residential usage.
• 3,000,000 operating cycles
• 6,000 x 6,000 mm max size
皇冠体育网 • High wind load tolerance than standard high speed doors at certain sizes

TECHNICAL SPECIFICATION TR SP
WIDTH (mm) 2,000–6,000
HEIGHT (mm) 1,800–6,000
OPENING SPEED (m/s) 1.5
CLOSING SPEED (m/s) 0.8 or as opening speed
DOOR STRUCTURE Galvanised steel
PANEL TYPE Aluminium sandwich panels
SANDWICH PANEL THICKNESS (mm) 40
TRACK GUIDES Aluminium
WIND LOAD EN12424:2000
• Class 3 (3,000 x 3,000 mm)
• Class 2 (6,000 x 6,000 mm)
OPERATING TEMPERATURE RANGE (°C) • -15 to +70, indoor drive
• -5 to +70, outdoor drive
• -35 to +70, drive & side frame heating systems
• Below -5, no windows
CONTROL UNIT • For servo motor
• Painted steel housing, 370 x 250 x 135 mm
• IP54 ingress protection
OPERATOR • Supply 240V/50–60Hz; 400V/50–60Hz; 0.75–1.5kW servo motor
• IP54 ingress protection
SAFETY • Built to EU standards - EN 13241 CN
• Photocells (2 pairs), 400 mm & 900 mm from floor level
• Door bottom safety sensor
• Winter auto-run function
• Partial opening function
• Flashing light
• Siren (optional)

Full Vision TP VI

For good insulation, allowing full light and vision through the door.
• 25,000 operating cycles
• Internal & external visibility
• Good light permeability, energy saving

TECHNICAL SPECIFICATION TP VI
WIDTH (mm) 2,000–6,000
HEIGHT (mm) 2,000–6,000
THERMAL INSULATION (R-VALUE) (m2. c/w) 0.20
WIND LOAD Class 2 (EN12424:2000)
WATERTIGHTNESS Class 3 (EN12425:2000)
WEIGHT OF DOOR LEAF (kg/m2) 17
TYPE OF VISION PANEL 40
TRACK GUIDES Double acrylic glass
ACRYLIC GLASS THICKNESS (mm) 3
WEIGHT OF VISION PANEL (kg/m3) 3.28
LIGHT TRANSMISSION TD65 80 %

Based on your selection, we recommend to add a loading bay shelter


Retractable

TS RE

For air-conditioned and ambient temperature environments.
• Double-reinforced PVC front cover
• 0.5 mm thick PVC sheet side covers
• Aluminium frame structure

TECHNICAL SPECIFICATION TS RE
WIDTH (mm) 3,000/3,200/3,400
HEIGHT (mm) 3,000/3,200/3,400/3,800/4,400
DEPTH 600
UPPER FLAP LENGTH (mm) 1,000
SIDE FLAP LENGTH (mm) 600
FRONT PVC SHEET THICKNESS (mm) 3
SIDE PVC SHEET THICKNESS (mm) 0.5
OPEN/CLOSE MECHANISIM Belt system
OPERATING TEMPERATURE RANGE (°C) -35 to +50

Inflatable

TS IN

Inflatable seal made for cold storage facilities where impeccable sealing is required.
• Military-grade Cordura® 1000D inflatable cushions
• 3-phase 380V 350W blower motor (1-phase 220V option available)
• Sandwich panel frame

TECHNICAL SPECIFICATION TS IN
WIDTH (mm) 3,410/3,610
HEIGHT (mm) 3,300/3,800/4,900
DEPTH 800
UPPER CUSHION (mm) 900
SIDE CUSHION (mm) 600
CORDURA® 1000D CUSHION MATERIAL THICKNESS (mm) 0.5
AVERAGE CUSHION INFLATION TIME (sec) 40
OPERATING TEMPERATURE RANGE (°C) -35 to +50